Inert Gas Argon IG55 Fire Extinguishing System Cylinder For Computer Room

Brand Name : Air Giant

Model Number : DYMP80/20, DYMP140/20, DYMP80/30, DYMP140/30

Certification : CAL,CMA,CNAS,ILAC-MRA,CCC

Place of Origin : China

MOQ : 1 set

Price : negotiation

Payment Terms : L/C,D/P,T/T,Western Union,Paypal,Credit card

Supply Ability : 300 sets per week

Delivery Time : 10-15 working days

Packaging Details : Plywood outer box with bubble bag or paper

Cylinder Volume : 80L;140L

Capacity : 22.9kg, 34.06kg

Pattern of extinguishing : Enclosed flooding

Agent : IG55(50% Nitrogen, 50% Argon )

Working pressure : 20MPa, 30MPa

Max. working pressure : 23.2MPa, 36.6 MPa

System start mode : Electrical automatic, electrical manual, mechanical emergency start

Color : Red

Contact Now

Inert Gas Argon IG55 Fire Extinguishing System Cylinder For Computer Room


Description


The extinguishing principle of inert gases focuses on reducing oxygen concentration in the affected zone.

When a fire starts, IG-55 rapidly penetrates the area and reduces the oxygen level percentage from the usual level of 21% to a limit that fluctuates between 13% and 11%, the amount sufficient for combustion to stop and to be safe for the people in the room. Thanks to the stratification of the gases (due to their density, argon rises and nitrogen falls) protection is achieved throughout the space, regardless of how high the ceiling is.

During its discharge, there is excellent visibility and, since it leaves no residue, there are no destructive effects to the equipment, which will continue functioning normally and, of course, there will be nothing to clean up.


Parameters


No. Specification IG55(50% nitrogen;50% argon)
1 Capacity 80Ltr 140ltr
2 Working Pressure 20MPa 30MPa 20MPa 30MPa
3 Device Model QMH20/80 QMH30/80 QMH20/140 QMH30/140
4 Filling Capacity of Gas 22.32kg 33.48kg 42kg 58.2kg
5 Outside Diameter of Cylinder Φ267mm Φ267mm Φ406mm Φ356mm
6 Height of Cylinder 1870mm 1870mm 1460mm 1925mm
7 Filling Rate 0.299kg/L 0.415kg/L 0.300kg/L 0.201kg/L
8 Spraying Time ≤120s
9 Power DC24V/1.6A
10 Nitrogen Pressure of Driving Device 6.0±1.0MPa(20℃)
11 Condition of Reserving Room for Container temperature: 0~50℃

Features and benefits


-- Suitable for occupied areas

-- Electrically nonconductive

-- Chemically inert

-- Colourless, odourless and flavourless

-- No residue to clean up after the discharge

-- Zero Ozone Depletion Potential (ODP)

-- No greenhouse effect

-- No global warming impact

-- No decomposition products

-- No fog and no loss of post-discharge visibility

-- Non corrosive/toxic

-- Stored as a gas

-- Suitable for occupied areas

-- Excellent post-discharge visibility

-- Very low refill cost

-- Easy to obtain anywhere in the world


Application


-- Data centers, server rooms

-- Substations, electrical rooms

-- Telecommunication facilities

-- Museums, libraries, archives

-- Art storage rooms

-- Precision instrument workshops

-- Flammable liquid or gas storage areas

-- Aircraft hangars, ship engine rooms

-- Railway control centers

-- Control rooms, UPS power rooms

-- Hospital operating rooms, MRI suites


Inert Gas Argon IG55 Fire Extinguishing System Cylinder For Computer Room


Package


We always pack it with polyfoam firstly and then put it into a wooden case. Sometimes, in order to meet with customers or the safety requirement, we will make a pallet for the goods.


Inert Gas Argon IG55 Fire Extinguishing System Cylinder For Computer Room



Company Introduction


Guangdong Air Giant Fire Equipment Co,.Ltd. is specialized in fire suppression system. Our Headquarter is located in Nansha District, Guangzhou, which is the south door of China mainland. Our company has complete and scientific quality management system.The sincerity, powerful strength and good quality are recognized by fire industry. All staffs welcome everyone from all directions and all industries to come here for visit, guidance and business cooperation.


Our company specializes in all kinds of Heptafluoropropane fire suppression systems,aerosol fire suppression systems, and we possess an experienced research and development team who have more than 20 years work experiences in national fire suppression career.


Inert Gas Argon IG55 Fire Extinguishing System Cylinder For Computer Room


China Inert Gas Argon IG55 Fire Extinguishing System Cylinder For Computer Room wholesale

Inert Gas Argon IG55 Fire Extinguishing System Cylinder For Computer Room Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Guangdong Air Giant Fire Equipment Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)